BCBL Troubleshooting Knowledge Base (Complete)

BCBL Troubleshooting Knowledge Base (Complete)

Sunstream FloatLift

Remote will not work

Steps:
  • Test UP/DOWN switch at powerpack (RC lockout ≈11V battery; pump cuts ≈9V).
  • Charge battery with 10A charger; tighten battery lugs; press RC power.
  • Re-program transmitter; replace FOB battery.
  • If still no, inspect RC for water damage; replace RC if required.
Resolution Check: Remote operates after charge/reprogram?
Escalation: If unresolved: Warranty check → replace RC/FOB; create ticket.
Notes: Solar cannot recover from >50% depletion—booster charge required.

Battery not keeping charge

Steps:
  • Verify AC outlet/GFI and charger LEDs.
  • Move solar to unobstructed sun; clean panel.
  • Booster charge 10A overnight; consider AC charger or extra panel.
  • Legacy early‑2024 FL10 dock/guide mount: send jumper if applicable.
Resolution Check: Battery holds charge for a week of normal use?
Escalation: If not: load/capacity test; replace battery/charger.
Notes: Target ≥500 CCA and ~160Ah reserve (model dependent).

Lift stops after split second

Steps: Low battery behavior. Fully charge with 10A; re-program FOB if needed.
Resolution Check: Runs normally after full charge?
Escalation: If not: escalate electrical diagnostics.

Battery terminal becomes hot

Steps: Clean/tighten cables/terminals; check for corrosion/undersized wire; load test battery.
Resolution Check: Terminals cool after fix under load?
Escalation: If not: replace failing battery; inspect connections.

Limited remote range

Steps: Replace FOB battery; hold transmitter higher; reduce EMI (power lines/towers).
Resolution Check: Range acceptable now?
Escalation: If not: inspect receiver/antenna; relocate powerpack if needed.

Fluid overflows reservoir

Steps: Initial overflow can occur after first full-down. Purge air, set level 1–2″ from top with lift down; inspect/tighten fittings.
Resolution Check: Level stable / no overflow?
Escalation: If not: service seals/fittings; check for overfill.

Only one side extends/retracts

Steps:
  • Reseat all four hydraulic QDs (fully seated).
  • Swap L/R fittings at pump and test:
  • If problem switches sides → pump/valve path.
  • If same side → cylinder/line path.
Resolution Check: Root cause isolated?
Escalation: If unresolved: service pump or cylinder accordingly.

Pump runs but lift doesn’t move

Steps: Undo/redo the four hydraulic QDs inside powerpack; ensure fully seated; check lock/check valve function.
Resolution Check: Movement restored?
Escalation: If not: valve/lock failure; escalate.

Lift not going all the way up

Steps: With lift down, reservoir 1–2″ from top; fully charge battery; confirm boat weight within lift capacity; check relief setting.
Resolution Check: Reaches full up under load?
Escalation: If not: verify pressure vs spec; escalate.

Uneven down speed / drifting (FL6 Orifice)

Steps: Perform FL6 Orifice Swap to correct side-to-side down-speed variance; verify QDs, flow-control orifices and down valves are clean/operational.
Resolution Check: Equalized descent after swap?
Escalation: If not: inspect down valves and orifices; escalate.
Notes: Service ref: FL6 Orifice Swap bulletin.

System – Battery

Low capacity / frequent discharge

Steps:
  • Use ≥500 CCA and ~160Ah reserve (varies by model); typical life ~3 years.
  • Check fluid every 3 months; fill to ~1″ from top (distilled water).
  • Capacity test: >12.5V & >75% hydrometer OR tester reads OK.
  • Booster charge 10A for 10 hrs; retest.
  • Replace if weak or >3 years.
Resolution Check: Holds charge after maintenance and booster?
Escalation: If not: replace battery; counsel on solar limits.
Notes: All lifts use one battery except FL10/FL13/SL18/SL24 use two.

System – Solar

Battery not recovering on solar

Steps:
  • Confirm direct sunlight hours; clean panel.
  • Polarity: red/white→+, black→−.
  • Panel open-circuit 16–20V in sun.
  • Add regulator (hot climates) or parallel panels (heavy use).
  • Reminder: solar cannot recover from >50% depletion.
Resolution Check: Recovery improved?
Escalation: If not: test battery/charger; inspect fuses/wiring.

System – Starter Solenoid

Motor won’t start

Steps:
  • Verify battery OK.
  • Check 12V+ to trip wire when pressing Up/Down.
  • Briefly bypass solenoid to test motor.
  • If motor runs with bypass → replace solenoid; if not → battery/cables/motor fault.
Resolution Check: Motor runs normally after corrections?
Escalation: If not: check for water intrusion; replace affected components.

System – Valves/Coils

Only moves one way / valve sticking

Steps:
  • Listen for coil/valve “click” Up/Down.
  • Swap valves (Up↔Down) to see if symptom follows; press plunger to free while out.
  • With inline gauges: Up builds lower gauge, Down builds upper. Replace non-shifting valve.
Resolution Check: Bidirectional motion restored?
Escalation: If not: check coil power/ground; escalate.

System – QD (Quick Disconnect)

Lift not moving / moves slightly

Steps:
  • Verify screw-type QDs are fully seated with wrench.
  • If an old snap-on QD is used, replace with screw-type set.
  • Note: operating screw QD unseated can blow inner seal (leak).
Resolution Check: Full motion restored after seating?
Escalation: If not: inspect QD internals and hoses; replace as needed.

System – Wet Powerpack

Water exposure suspected

Steps:
  • Look for rust/corrosion on coils/solenoid; water in box; water in motor end cap.
  • If severe: replace pump assembly, RC, battery.
  • If light: replace rusty coils/solenoid; clean terminals; anti-corrosion spray; warn about progressive failures.
Resolution Check: Stable operation after remediation?
Escalation: If not: replace affected components proactively.

Remote (RC308/RC400/RC401)

Fob will not operate lift

Steps:
  • If UP/DOWN switch works, battery likely low—charge first.
  • Re-program known-good transmitter; replace FOB battery.
  • Inspect for water damage on RC; verify wiring.
Resolution Check: Fob operates after program/battery?
Escalation: If not: replace RC under warranty; create ticket.

Remote (RC306 and earlier)

Switch+Fob both dead

Steps:
  • Verify powerpack battery and main fuse.
  • Verify RC wiring continuity/pinout.
  • Coil Voltage Test: 12V+ on Down coil when pressing Down (not Up) and vice versa.
  • 12V+ on starter-solenoid trip when pressing Up/Down.
  • Lights output test (RC305/RC306) and fuse if applicable.
Resolution Check: Outputs present and motor runs?
Escalation: If outputs missing: repair RC wiring/fuse; replace RC if failed.

Remote (General)

Switch broken but fob works

Steps: UP/DOWN switch likely broken or lead off; replace switch or full RC assembly if preferred.
Resolution Check: Manual switch restored?
Escalation: If not: replace RC assembly.

Sunstream SunLift SLX

Manual switch does not operate

Steps: RC box power ON; battery >12.5V; wires to solenoids tight/corrosion-free.
Resolution Check: Operates via manual after fixes?
Escalation: If not: solenoid/RC power path diagnostics.

Key fob does not operate

Steps: Confirm manual switch works; re-program FOB; replace FOB battery.
Resolution Check: Fob runs lift now?
Escalation: If not: RC receiver diagnostics / replacement.

Key fob limited range

Steps: Replace FOB battery; move position/height; reduce EMI sources.
Resolution Check: Range acceptable?
Escalation: If not: inspect antenna/receiver.

Battery does not keep charge

Steps: Verify charger/solar connections; ensure solar in direct sun; booster charge if <50% SOC.
Resolution Check: Holds charge after cycle?
Escalation: If not: test charger and battery; replace as needed.

Hoses difficult to connect

Steps: Depressurize via RC box; wrench on QDs; clear debris from threads.
Resolution Check: QDs connect smoothly?
Escalation: If not: replace damaged fittings/QDs.

Fluid in bottom of power pack

Steps: New install air purge may burp fluid; set level after purge; tighten leaking fittings/gaskets.
Resolution Check: Dry after retest?
Escalation: If not: service seals/fittings.

Battery terminal becomes hot

Steps: Clean/tighten terminals; load test battery; inspect wiring gauge/resistance.
Resolution Check: No abnormal heat?
Escalation: If not: replace battery; inspect cable ends.

Sunstream SwiftShield

Does not operate with manual switch

Steps: Verify RC power is ON; check battery voltage.
Resolution Check: Operates via manual?
Escalation: If not: pump power/solenoid diagnostics.

Does not operate via key fob

Steps: Confirm manual works; re-program fob; replace fob battery.
Resolution Check: Fob works after steps?
Escalation: If not: RC receiver diagnostics.

Cover does not actuate after lift up

Steps: Increase pump relief 1/4 turn (~250 psi); ensure fluid above intake; verify SQBB valve reaches ~3350 psi and replace if required.
Resolution Check: Cover actuates fully?
Escalation: If not: escalate valve/pressure testing.

Lift lowers before fully uncovered

Steps: Verify system pressure and sequencing valve function; adjust per manual.
Resolution Check: Holds until fully uncovered?
Escalation: If not: escalate.

Fluid found in bottom of power pack

Steps: Initial burp possible; after purge, reset level and check for leaks; tighten fittings/gaskets.
Resolution Check: Dry after retest?
Escalation: If not: service seals/fittings.

Battery terminal becomes hot

Steps: Clean/tighten terminals/cables; load-test battery.
Resolution Check: No abnormal heat after fix?
Escalation: If not: replace battery; inspect resistance path.

Roller doesn’t pull tight / stops

Steps: Torque roller per manual; ensure cover not catching fin plates; add Wind Guide accessory if needed.
Resolution Check: Smooth operation restored?
Escalation: If not: escalate.

Cover won’t catch bow

Steps: Verify roller torque; adjust bow guide ropes (3E); add elastic cord (3F).
Resolution Check: Catches bow consistently?
Escalation: If not: escalate.

Cover won’t pop over rub rail shoulders

Steps: Adjust bow guide ropes per 3E; widen spreader bar if necessary.
Resolution Check: Pops over shoulders?
Escalation: If not: escalate.

FLOE VSD Lifts (6000/7500/10000)

Lift won’t go up/down

Steps:
  • Wired remote key ON.
  • Each battery 12.7–13.8V; clean/tighten battery wiring.
  • Verify ASC plugs to limit switch and remotes seated.
  • Verify motor wiring under cover.
  • Check/reset breaker/fuse. If it trips, investigate overload, brake not releasing (listen for click), drivetrain/cable friction.
Resolution Check: Operates after checks?
Escalation: If not: escalate to technician.

Lift only works in one direction

Steps: Use ASC limit-switch bypass plug to test. CAUTION: do not run to hard stops. If both directions work with bypass, replace/adjust limit switches.
Resolution Check: Both directions with bypass?
Escalation: If not: motor/control path issue—escalate.

FLOE Vertical Winch Lifts (V2000–V4600/V2602)

Lift won’t go up/down

Steps:
  • Verify battery health/charge; clean/tighten wiring.
  • Inspect winch/ASC connections and fuse.
  • Check brake engagement and mechanical binding in cable/pulley path.
  • Confirm load within rating and duty cycle not exceeded.
Resolution Check: Moves after checks?
Escalation: If not: limit switch/ASC/winch diagnostics.

FLOE Roll-In Dock

Dock not level / legs won’t adjust

Steps: Use 1‑1/8″ socket or Floe Speed Wrench; CW lowers / CCW raises; alternate wheel‑kit legs to reduce binding; drill in clutch mode; do not force at end‑travel.
Resolution Check: Level achieved?
Escalation: If not: inspect leg threads/wheel kit; escalate.

Dock stuck in mud / won’t move

Steps: If wheels sunk, slowly rock/pull; use winch/vehicle with steady pull (no jerking). Use helpers; consider airtight wheels for mud.
Resolution Check: Dock freed?
Escalation: If not: schedule service.

FLOE Canopy

Fabric sagging / pooling

Steps: Square frame; adjust front/rear bow tension; re‑lace/retension fabric; inspect for stretched fabric/wind damage; secure hardware.
Resolution Check: Fabric taut and shedding water?
Escalation: If not: replace fabric or bent bows; order parts.

Frame misaligned / install difficult

Steps: Loosen, square side frames, equalize spacing; seat cross members; align then retighten; check for bent tubes.
Resolution Check: Frame square & secure?
Escalation: If not: replace damaged components.

Sunstream SunPort2

Hard to load/unload PWC

Steps: Verify pivoting tail alignment; roller configuration matches hull strakes; mounts correct (Slide vs Duraflexx). Adjust roller spacing/tail angle; retest.
Resolution Check: Loads/rolls off smoothly?
Escalation: If not: adjust mounts; inspect rollers for wear.

Sunstream PWC 1200/1300/1600

Won’t go up/down

Steps: Battery >12.5V; connections tight; check starter‑solenoid trip while pressing Up/Down; inspect limit/stop wiring/connectors; verify valve coil power.
Resolution Check: Operates after electrical checks?
Escalation: If not: replace faulty solenoid/valve; escalate.

Only works one direction

Steps: Listen for Up/Down valve clicks; swap suspect valve/coil; verify QDs are tight; inspect controller output for Up vs Down.
Resolution Check: Both directions restored?
Escalation: If not: replace failed coil/valve; escalate.

Drifts down / won’t hold

Steps: Inspect PO check valve; swap #1/#2 and test if drift follows; check hoses/fittings for leaks.
Resolution Check: Holds position after repair?
Escalation: If not: cylinder blow‑by test; replace seals/cylinder.

Charger not charging

Steps: LED ON? Confirm GFI circuit. Wiring: red→+, black→−. With charger connected battery should read >13V; unplug and compare. Replace charger if no change.
Resolution Check: Maintains charge with known‑good charger?
Escalation: If not: replace charger or battery.

Sunstream Helix‑P (HP8/HP12)

Uneven lifting / no movement

Steps: Cap beams square/lagged; crossbeams seated on stop blocks; cables routed/tensioned (fine adjust blocks); check hydraulics/electrical; purge air; run setup.
Resolution Check: Even movement after retest?
Escalation: If not: rotary motor/valve diagnostics; escalate.

Cables slack / unspooling on lower

Steps: Install counterweights in catwalk ends (motor side); maintain tension when lowering; supervise first water cycle; re‑tension cables.
Resolution Check: No unspooling after counterweights?
Escalation: If not: reroute/re‑tension; inspect pulleys/guards.

Join Our Newsletter

Sign up for our newsletter to receive notifications of upcoming promos and sales.
Office Location & Hours
  • 810 Riverside Ave, Sicamous, BC V0E 2V1
  • We are open - Come visit us!
    Monday - 9 am - 5 pm
    Tuesday - 9 am - 5 pm
    Wednesday - 9 am - 5 pm
    Thursday - 9 am - 5 pm
    Friday - 9 am - 5 pm
    Saturday - 9 am - 5 pm (appointments only)
    Sunday - Closed
© 2025 BC Boat Lift and Dock. All Rights Reserved.
Get a Free Quote or Speak With The Team
We Typically Respond Within 24 Hours.
For more information, view our Privacy Policy and Terms of Service.